Product Series
Epoxy glass flake anti-corrosion paint (two-component)
Product Features:
Excellent acid resistance, alkali resistance and solvent resistance; excellent shielding property, can prevent the intrusion of water vapor or chemical gas; resistance to splashing of gasoline, aviation kerosene, lubricating oil and related products; good wear resistance and excellent durability It can be used as a primer by itself.
Performance parameters:
1. Color and appearance: gray or iron red, the paint film is smooth and smooth
2. Non-volatile matter: ≥60%
3. Specific gravity: about 1.55kg/L
4. Drying time: surface dry ≤4 hours; solid dryness ≤24 hours (under 25℃)
5. Adhesion: Grade 1
6. Flexibility: ≤4mm
7. Impact strength: 50kg•cm
8. Acid resistance (25%H2SO4, 30d): no foaming, no falling off
9. Alkali resistance (25%NaOH, 30d): no foaming, no falling off
10. Salt water resistance (3%NaCl, 30d): no foaming, no falling off
Construction Instructions:
1. Surface treatment: The previous paint film is completely dry, and the oil stains on the paint film are removed.
2. Substrate temperature: 3°C higher than the dew point.
3. Coating method: can be brushed, rolled or sprayed.
4. Thinner: The epoxy paint thinner is adjusted to the appropriate viscosity for use.
5. Coating thickness: Mix evenly according to the ratio of A and B. After curing for 20 minutes, it is generally advisable to coat twice. The dry film thickness is 60-120um.
6. Theoretical dosage: about 3.5㎡/kg, (calculated by dry film 60um).
7. Overcoating interval: 16 hours at 25℃, the longest is unlimited.
8. The supporting paint for the front road: epoxy zinc-rich primer, epoxy rust primer.
Security:
1. The construction site should have good ventilation facilities.
2. Construction workers should wear masks, glasses, gloves and other protective equipment to avoid skin contact and inhalation of paint mist and solvents.
3. Smoking is strictly prohibited on the construction site, and all sources of ignition are isolated.